BSCs are open workspaces designed to protect laboratory personnelthrough the use of directional air flow and High Efficiency Particulate Air filters.

  • 〇
  • ╳

Key considerations for selecting appropriate PPE include

  • Characteristics of the biological agent
  • Type of work being carried out
  • Availability of national regulations
  • All of the above are correct

Essential biosafety equipment do not include

  • PPE
  • Autoclave
  • Bench
  • Biological safety cabinet

HEPA filter performance of a minimum efficiency of 99.97% should be used

  • 〇
  • ╳

Things to avoid when using a BSC

  • Use open flame
  • Rapid arm movements
  • Block the grills
  • All of the above mentioned

Which of the following description of the autoclave is incorrect?

  • Do not overload the autoclave
  • Use separate autoclaves for ‘clean’ and ‘dirty’ loads
  • No need to monitor autoclave sterization regularly
  • Do not operate overnight

Different types of glove may be needed for different tasks or with other occupational hazards, such as heat or sharps.

  • 〇
  • ╳

Air particles are caught by HEPA through which mechanism?

  • Diffusion
  • Interception
  • Impaction
  • All of the above are correct

PPE is used only in BSL-2,3 and 4 biological laboratories

  • 〇
  • ╳

Gloves should always be inspected before use to check that they are intact.

  • 〇
  • ╳

When use combinations of PPE needs to consider complementing one another

  • 〇
  • ╳

Which description is incorrect?

  • Minimum distance between BSC and door is 1.1 m
  • Minimum distance between 2 side-by-side BSCs is 1 m
  • 2 BSCs put in the opposite site along the wall, the minimum space between 2 persons is 3.1 meters
  • The airflow curtain that helps provide protection when working in a BSC is fragile

Work surfaces and interior walls need to be disinfected only after each use

  • 〇
  • ╳

The minimum space between BSC and door is 1.1 meter and the same distance between 2 side-by side BSCs.

  • 〇
  • ╳

Which level of biosafety laboratory required to use PPE?

  • BSL-1
  • BSL-2
  • BSL-3
  • All of the above are correct

Autoclave sterilization condiction?

  • 121°C for 60 minutes
  • 100°C for 60 minutes
  • 85°C for 60 minutes
  • 121°C for 15 minutes
  • 〇
  • ╳

If an autoclave used for sterilize the infectious substances, Its exhaust should be filtered through a filter with membrane size of

  • 0.1 micron
  • 0.2 micron
  • 0.3 micron
  • 0.4 micron

Autoclaving is the most dependable method of sterilizing laboratory equipment and decontaminating biohazard wastes.

  • 〇
  • ╳

Which form of PPE is one of the most critical and easily implemented ?

  • Footware
  • Eye protection
  • Lab coat
  • Respiratory protection

After moving a BSC within the laboratory, it is not nessersary to certified the BSC.

  • 〇
  • ╳

Which class of BSC can not protect ptoducts?

  • Class III
  • Class I
  • Class II A1
  • Class II B1

When infectious materials are sterilized, exhaust of an autoclave should be filtered through a filter with 0.2 micron membrane

  • 〇
  • ╳

Which class of BSC do not have HEPA filtered supply air?

  • Class II
  • ClassIII
  • Class I
  • Class II B1

The proper type of PPE must be chosen and personnel must be trained in its proper use and know how to detect any faults

  • 〇
  • ╳

Which one is not a key consideration for selecting PPE?

  • Volumes and concentrations of the biological agent
  • Color
  • Other PPE being worn
  • Individual needs of the laboratory personnel

Which of the following descriptions of the functions of a biological safety cabinet is incorrect?

  • Air in the Class I, Class II B2, and Class III BSC is 100% exhausted
  • There are 3 classes of BSC
  • None of BSC can be applied to handle volatile toxic chemicals
  • Class II A1 and A2 BSCs can be a thimble connected

The laboratory director should ensure that the adequate equipment is provided and used properly.

  • 〇
  • ╳

Which PPE is not a core requirement?

  • Respiratory protection
  • Gloves
  • Lab coat
  • Footware

All classes of BSC can protect personnel, enviroment and product

  • 〇
  • ╳